1. Overview of ST/STC brushed generators
The company has produced ST (single-phase) and STC (three-phase) generators for nearly 40 years, with an annual output of about 10,000 generators, with mature technology and superior performance.
Generator feature description:
1. Steel shell structure.
2. Third harmonic excitation.
3. Strong ability to start asynchronous machine.
4. Can adapt to harsh environments.
5. Superior cost performance.
2. Specifications
model | Capacity KVA | Power KW | Voltage V | Current A | Phase | Frequency HZ | Protection grade IP | Insulation class | Pressure regulation rate% |
STC5 | 6.25 | 5 | 400 | 9 | 3 | 50 | 21 | B | 5 |
STC7.5 | 9.375 | 7.5 | 400 | 13.5 | 3 | 50 | 21 | B | 5 |
STC10 | 12.5 | 10 | 400 | 18 | 3 | 50 | 21 | B | 5 |
STC12 | 15 | 12 | 400 | 21.6 | 3 | 50 | 21 | B | 5 |
STC15 | 18.75 | 15 | 400 | 27 | 3 | 50 | 21 | B | 5 |
STC20 | 25 | 20 | 400 | 36 | 3 | 50 | 21 | B | 3 |
STC24 | 30 | 24 | 400 | 43.2 | 3 | 50 | 21 | B | 3 |
STC30 | 37.5 | 30 | 400 | 54 | 3 | 50 | 21 | B | 3 |
STC40 | 50 | 40 | 400 | 72 | 3 | 50 | 21 | B | 3 |
STC50 | 62.5 | 50 | 400 | 90 | 3 | 50 | 21 | B | 2 |
STC64 | 80 | 64 | 400 | 115.2 | 3 | 50 | 21 | B | 2 |
STC75 | 93.75 | 75 | 400 | 136 | 3 | 50 | 21 | B | 2 |
STC90 | 112.5 | 90 | 400 | 162 | 3 | 50 | 21 | B | 2 |
STC100 | 125 | 100 | 400 | 180 | 3 | 50 | 21 | B | 2 |
STC120 | 150 | 120 | 230 | 216 | 1 | 50 | 21 | B | 5 |
ST-5 | 5 | 5 | 230 | 21.7 | 1 | 50 | 21 | B | 5 |
ST-10 | 10 | 10 | 230 | 43.5 | 1 | 50 | 21 | B | 5 |
ST-12 | 12 | 12 | 230 | 52.2 | 1 | 50 | 21 | B | 5 |
ST-24 | 24 | 24 | 230 | 104.4 | 1 | 50 | 21 | B | 5 |
1. Overview of ST/STC brushed generators
The company has produced ST (single-phase) and STC (three-phase) generators for nearly 40 years, with an annual output of about 10,000 generators, with mature technology and superior performance.
Generator feature description:
1. Steel shell structure.
2. Third harmonic excitation.
3. Strong ability to start asynchronous machine.
4. Can adapt to harsh environments.
5. Superior cost performance.
2. Specifications
model | Capacity KVA | Power KW | Voltage V | Current A | Phase | Frequency HZ | Protection grade IP | Insulation class | Pressure regulation rate% |
STC5 | 6.25 | 5 | 400 | 9 | 3 | 50 | 21 | B | 5 |
STC7.5 | 9.375 | 7.5 | 400 | 13.5 | 3 | 50 | 21 | B | 5 |
STC10 | 12.5 | 10 | 400 | 18 | 3 | 50 | 21 | B | 5 |
STC12 | 15 | 12 | 400 | 21.6 | 3 | 50 | 21 | B | 5 |
STC15 | 18.75 | 15 | 400 | 27 | 3 | 50 | 21 | B | 5 |
STC20 | 25 | 20 | 400 | 36 | 3 | 50 | 21 | B | 3 |
STC24 | 30 | 24 | 400 | 43.2 | 3 | 50 | 21 | B | 3 |
STC30 | 37.5 | 30 | 400 | 54 | 3 | 50 | 21 | B | 3 |
STC40 | 50 | 40 | 400 | 72 | 3 | 50 | 21 | B | 3 |
STC50 | 62.5 | 50 | 400 | 90 | 3 | 50 | 21 | B | 2 |
STC64 | 80 | 64 | 400 | 115.2 | 3 | 50 | 21 | B | 2 |
STC75 | 93.75 | 75 | 400 | 136 | 3 | 50 | 21 | B | 2 |
STC90 | 112.5 | 90 | 400 | 162 | 3 | 50 | 21 | B | 2 |
STC100 | 125 | 100 | 400 | 180 | 3 | 50 | 21 | B | 2 |
STC120 | 150 | 120 | 230 | 216 | 1 | 50 | 21 | B | 5 |
ST-5 | 5 | 5 | 230 | 21.7 | 1 | 50 | 21 | B | 5 |
ST-10 | 10 | 10 | 230 | 43.5 | 1 | 50 | 21 | B | 5 |
ST-12 | 12 | 12 | 230 | 52.2 | 1 | 50 | 21 | B | 5 |
ST-24 | 24 | 24 | 230 | 104.4 | 1 | 50 | 21 | B | 5 |